QM BenchQuality engineering tools

True position

GD&T position tolerance of a feature

Position Ø = 2 · √(dX² + dY²); allowed = t + bonus

The true position is the theoretically exact location of a feature, defined by basic dimensions from the datums. A position tolerance in the feature control frame is usually a cylindrical zone of diameter t around that location; the axis or centre of the actual feature must lie inside it.

Because the zone is a diameter and the measured deviation is a distance from the centre, the position value is twice the radial deviation. A modifier changes the zone with the size of the feature: at MMC (Ⓜ) the stated tolerance applies at the maximum material size and grows by the bonus as the actual mating size moves towards least material; at LMC (Ⓛ) it works the other way round.

Bonus tolerance for holes and pins

  • Hole at MMC: bonus = actual mating size − smallest permitted hole.
  • Pin at MMC: bonus = largest permitted pin − actual mating size.
  • Hole at LMC: bonus = largest permitted hole − actual minimum material size.
  • Pin at LMC: bonus = actual minimum material size − smallest permitted pin.
  • No modifier (RFS): no bonus; the stated tolerance applies at any size.

Virtual condition

At MMC the worst mating boundary is the virtual condition: for a hole MMC size minus the position tolerance, for a pin MMC size plus the position tolerance. A functional gauge pin or hole is made at this size. With LMC the corresponding boundary keeps a minimum wall thickness instead.

Which standard

The definitions come from ASME Y14.5 and the ISO GPS standards (ISO 1101 for position, ISO 2692 for the maximum and least material requirements). The basic position formula is the same; the rules for size, datums and default conditions differ in detail, so check which system the drawing refers to.

Example

Hole Ø10 +0.2/0, position Ø0.1 at MMC. Measured dX 0.06, dY 0.08: position Ø0.20. Actual mating size 10.12, bonus 0.12, allowed Ø0.22: in tolerance.

Common mistake

Comparing the radial deviation, or dX and dY separately, with the diametral tolerance. A square ±0.05 zone is not the same as a Ø0.1 zone: the round zone is larger in the diagonal directions.

Calculate it

True Position Calculator (GD&T): Position Ø from CMM deviations, MMC / LMC bonus, pass / fail for many features.