QM BenchQuality engineering tools

CQI special process assessments

Heat treating, plating, coating, welding, molding and casting have one thing in common: you cannot fully check the result on the finished part. The AIAG CQI assessments make sure the process itself is under control. Here is what they are, who asks for them, how often, and a free self-assessment checklist to start with.

By Ľubomír Blažek · Process quality team leader, automotive · updated 2026-11-13

The six main assessments

CQI-9Heat treatmentHeat Treat System AssessmentCarburizing, carbonitriding, nitriding, induction hardening, through hardening, annealing, tempering and similar processes, in-house or at a commercial heat treater.Free self-assessment checklist
CQI-11PlatingPlating System AssessmentElectroplating and related wet processes, for example zinc and zinc alloy, nickel, chrome and tin, including pretreatment and post-treatment such as passivation.Checklist planned
CQI-12CoatingCoating System AssessmentOrganic and conversion coatings, for example e-coat, powder coating, spray painting, phosphating and zinc flake.Checklist planned
CQI-15WeldingWelding System AssessmentArc, resistance, laser and other welding processes used for metal parts and assemblies.Checklist planned
CQI-23MoldingMolding System AssessmentPlastic injection molding and related molding processes.Checklist planned
CQI-27CastingCasting System AssessmentMetal casting, for example aluminium high and low pressure die casting, gravity and sand casting.Checklist planned

The series has further documents, for example for soldering and brazing. The name, scope and edition of each manual are set by AIAG; check the current edition before you assess.

What a CQI assessment is

A CQI special process assessment is a structured self-audit of one manufacturing technology. Each manual has the same basic structure: questions on the management system around the process, questions on the shop floor and material handling, questions on the equipment, a job audit that follows one real order, and process tables. The process tables say which parameters to monitor, how often, and which tests to run on the parts, for each variant of the process.

Every item is rated as satisfactory, not satisfactory, needs immediate action or not applicable. There is no points score: every gap needs its own corrective action.

Who requires it

IATF 16949 does not name the CQI manuals. The requirement comes from the customers: several automotive OEMs, especially in North America, ask in their customer-specific requirements that each supplier using a special process runs the matching CQI assessment, and that it flows the requirement down to its own special process suppliers. Other customers and tier 1 suppliers adopt the same approach in their supplier manuals. Read the current customer-specific requirements of each customer to know whether, which edition, and how.

How often

The common rule is a self-assessment once a year, plus a new assessment when the process changes significantly (new equipment, new location, new process variant) or after a serious quality problem. Some customers set their own interval, or require an assessment by their own or a third-party assessor. The results and the action plan should be ready for review by the customer and by the IATF certification body.

How to run one in six steps

  1. Get the current manual. Buy the current edition of the AIAG manual for your process and read the customer-specific requirements; they decide the edition, the interval and who may assess.
  2. Name a qualified assessor. Someone who knows the process and the manual. Many customers expect formal training and, for some processes, a minimum of experience.
  3. Assess on the shop floor. Go through the system questions with evidence, then the job audit: follow one real order from receipt to shipment and compare it with the requirements.
  4. Check the process tables. For every process in use, compare monitoring and test frequencies with the tables, and use the stricter value where the customer specification differs.
  5. Rate and plan actions. Rate each item. Every not satisfactory item gets a corrective action with owner and due date; an item that needs immediate action gets containment first.
  6. Keep it and repeat. Keep the report and evidence ready for customer and IATF auditors and repeat the assessment at the required interval or after major changes.

How it fits IATF 16949 and supplier audits

RequirementLink to the CQI assessment
IATF 16949, 4.3.2Customer-specific requirements must be evaluated and included in the quality management system. This is where most CQI requirements come from.
IATF 16949, 8.3Manufacturing process design: process FMEA, control plan, process specifications and capability for the special process are designed and checked during development.
ISO 9001 / IATF 16949, 8.5.1Control of production, including validation and periodic revalidation of processes whose result cannot be fully verified afterwards. Heat treatment, plating, coating, welding, molding and casting are classic examples.
IATF 16949, 8.5.1.1 to 8.5.1.5Control plan, standardised work, verification after job set-up and shutdown, and total productive maintenance: all checked in detail by a CQI assessment.
IATF 16949, 8.4Supplier control: flow the CQI requirement down to sub-tier special process suppliers and verify it, for example by asking for their self-assessment or with a second-party audit.

For a supplier quality engineer the CQI assessment is a strong input to supplier selection and monitoring. Ask a special process supplier for its latest self-assessment and the status of the actions before you approve it, and focus your own process audit or capability assessment on the items it rated weakest. For the full supplier life cycle see the supplier quality hub.

Frequently asked questions

What does CQI stand for?

Continuous Quality Improvement. AIAG publishes a series of CQI documents; the special process assessments are the ones automotive customers use to check heat treating, plating, coating, welding, molding, casting and some other processes whose result cannot be fully verified on the finished part.

Is a CQI assessment mandatory?

Not by IATF 16949 itself. It becomes mandatory through customer-specific requirements: several OEMs, particularly North American ones, require their suppliers and sub-tier suppliers to run the CQI assessment for each special process they use. Check the current requirements of each customer.

How often must the assessment be done?

Typically once a year as a self-assessment, and again after major process changes, new equipment or quality problems. Some customers ask for a different interval or for an assessment by an external or customer assessor, so the customer-specific requirements decide.

Does a heat treat supplier need its own CQI-9?

Yes. The requirement applies to whoever runs the special process: an in-house heat treat shop and a commercial heat treater both need their own assessment. The organisation that buys the service must make sure the sub-tier supplier has done it and that its findings are closed.

Who can do the assessment?

A qualified assessor who knows the process and the manual, often an internal auditor with special process experience. The manuals and customers set the qualification expectations, such as training on the manual and process experience, and some customers accept only their own or third-party assessors.

Is CQI the same as a VDA 6.3 process audit?

No. VDA 6.3 is a general process audit for any process with a points-based score. CQI special process assessments go much deeper into one technology, with process tables that set monitoring and test frequencies. Many suppliers need both, depending on their customers.

Is there a pass score?

The CQI special process assessments are not based on a pass score. Each item is rated, and every item that is not satisfactory needs a corrective action that is tracked to closure. Some customers add their own scoring or escalation rules.

This page explains the assessments in our own words. It does not reproduce or replace the AIAG manuals, which you need for the actual assessment. CQI is a publication series of AIAG; QM Bench is not affiliated with AIAG.